product details

CQB-G high temperature magnetic drive pump

CQB-G high temperature magnetic drive centrifugal pump adopts multiple circulation cooling structure, which ensures the reliability and stability of prime power and magnetic drive. At the same time, column pin coupling is used to reduce the noise and vibration of the pump. The combination of the detachable and pin coupling makes the structure of the pump grow and is more conducive to the heat dissipation of the pump. At the same time, it is also very convenient for users to repair or replace parts. In the outer rotor part of the pump, the cooling fan blade is also designed to ensure the stability of the magnetic steel. This series is suitable for conveying high temperature medium, temperature ≤ 200 ℃.

021-62586878

1、 CQB-G high temperature magnetic drive centrifugal pump product overview:

CQB-G high temperature magnetic drive centrifugal pump adopts multiple circulation cooling structure, which ensures the reliability and stability of prime power and magnetic drive. At the same time, column pin coupling is used to reduce the noise and vibration of the pump. The combination of the detachable and pin coupling makes the structure of the pump grow and is more conducive to the heat dissipation of the pump. At the same time, it is also very convenient for users to repair or replace parts. In the outer rotor part of the pump, the cooling fan blade is also designed to ensure the stability of the magnetic steel. This series is suitable for conveying high temperature medium, temperature ≤ 200 ℃.

2、 Installation and commissioning of CQB-G high temperature magnetic drive centrifugal pump:

(1) It should be installed horizontally. The lubricating oil level of cooling box should be checked before start-up. If the oil level is too low, it should be replenished in time. Before starting the pump, the cooling water circuit should be opened first. The opening degree of the inlet pipe valve should be adjusted according to the temperature of the cooling water pipe after the pump works normally.

(2) When the suction liquid level is higher than the axis line of the pump, open the valve of the suction pipe before starting. If the suction liquid level is lower than the pump axis line, the pipeline should be equipped with bottom valve.

(3) The pump should be checked before use. The wind blade of the motor should rotate flexibly without jamming and abnormal sound. All fasteners should be tightened.

(4) Check whether the motor rotation direction is consistent with the magnetic pump steering mark.

(5) After the motor starts, slowly open the discharge valve. After the pump enters the normal working state, adjust the discharge valve to the required opening. Shut off the water pipe and then shut off the valve.

3、 Model determination of CQB-G high temperature magnetic drive centrifugal pump

图片50.png

model

flow Q m3 /h

lift H m

NPSH NPSH m

speed n r/min

Shaft power Pa Kw

efficiency η %

With motor power Kw








Media density g/cm3








≤1

≤1.3

≤1.84

CQB-G 32-20-125

1.9 3.2 3.8

22 20 18.5

0.5

2900

0.49 0.58 0.62

23 30 31

Y801-2YB0.75

Y802-2YB1.1

Y90S-2YB1.5

CQB-G 32-20-160

1.9 3.2 3.8

34 32 29

0.5

2900

0.84 0.99 1.03

21 28 29

Y802-2YB1.1

Y90S-2YB1.5

Y90L-2YB2.2

CQB-G 40-20-105

3.8 6.3 7.5

13 12.5 11

0.5

2900

0.42 0.55 0.56

32 29 40

Y801-2YB0.75

Y802-2YB1.1

Y90S-2YB1.5

CQB-G 40-25-125

3.8 6.3 7.5

22 20 18.5

0.5

2900

0.81 0.98 1.05

28 35 36

Y802-2YB1.1

Y90L-2YB2.2

Y100L-2YB3.0

CQB-G 40-25-160

3.8 6.3 7.5

34 32 29

0.5

2900

1.41 1.72 1.79

25 32 33

Y90L-2YB2.2

Y100L-2YB3.0

Y112M-2YB4.0

CQB-G 40-25-200

3.8 6.3 7.5

52.5 50 48

0.5

2900

3.02 3.43 3.77

18 25 26

Y112M-2YB4.0

Y132S1-2YB5.5

Y132S2-2YB7.5

CQB-G 50-40-85

7.5 12.5 15

9 8 7.5

3.5 3.5 4.0

2900

0.46 0.56 0.61

40 49 50

Y801-2YB0.75

Y802-2YB1.1

Y90S-2YB1.5

CQB-G 50-32-105

7.5 12.5 15

13 12.5 11

3.5 3.5 4.0

2900

0.760 0.91 0.94

35 47 48

Y802-2YB1.1

Y90S-2YB1.5

Y90L-2YB2.2

CQB-G 50-32-125

7.5 12.5 15

22 20 18.5

3.5 3.5 4.0

2900

1.49 1.62 1.63

30 42 43

Y90L-2YB2.2

Y100L-2YB3.0

Y112M-2YB4.0

CQB-G 50-32-160

7.5 12.5 15

34 32 29

3.5 3.5 4.0

2900

2.48 2.79 2.96

28 39 40

Y100L-2YB3.0

Y112M-2YB4.0

Y132S1-2YB5.5

CQB-G 50-32-200

7.5 12.5 15

52.5 50 48

3.5 3.5 4.0

2900

5.10 5.49 6.13

21 31 32

Y132S2-2YB7.5

Y132S2-2YB7.5

Y160M1-2YB11

CQB-G 50-32-250

7.5 12.5 15

82 80 78.5

3.5 3.5 4.0

2900

9.57 10.89 13.32

17.5 25 26

Y160M2-2YB3.0

Y160M2-1YB8.5

Y180M-2YB5.5

CQB-G 65-50-125

15 25 30

22 20 18.5

3.5 3.5 4.0

2900

2.25 2.67 2.91

40 51 52

Y100L-2YB3.0

Y112M-2YB4.0

Y132S1-2YB5.5

CQB-G 65-50-160

15 25 30

34 32 29.5

3.5 3.5 4.0

2900

4.34 5.07 5.48

32 43 44

Y132S1-2YB5.5

Y132S2-2YB7.5

Y160M1-2YB11

CQB-G 65-40-200

15 25 30

53 50 47

3.5 3.5 4.0

2900

8.66 9.20 10.1

25 37 38

Y160M1-2YB11

Y160M2-2YB15

Y160L-2YB18.5

CQB-G 65-40-250

15 25 30

82 80 78.5

3.5 3.5 4.0

2900

13.4 14.72 16.88

25 37 38

Y160L-2YB18.5

Y180M-2YB22

Y200L1-2YB30

CQB-G 80-65-125

30 50 60

22.5 20 18

4.0 4.0 4.5

2900

4.48 5.24 5.55

41 52 53

Y132S1-2YB5.5

Y132S2-2YB7.5

Y160M1-2YB11

CQB-G 80-65-160

30 50 60

34 32 29

4.0 4.0 4.5

2900

7.72 9.08 9.67

36 48 49

Y160M1-2YB11

Y160M2-2YB15

Y160L-2YB18.5

CQB-G 80-50-200

30 50 60

53 50 47

4.0 4.0 4.5

2900

12.03 14.80 16.34

36 46 47

Y160L-2YB18.5

Y180M-2YB22

Y200L1-2YB30

CQB-G 80-50-250

30 50 60

84 80 75

4.0 4.0 4.5

2900

19.06 23.08 26.07

36 46 47

Y200L1-2YB30

Y220L2-2YB37

Y225M-2YB45

CQB-G 100-80-125

60 100 120

23 20 16.5

4.0 4.0 4.5

2900

8.35 9.73 9.46

45 56 57

Y160M1-2YB11

Y160M2-2YB15

Y200L1-2YB30

CQB-G 100-80-160

60 100 120

35 32 28

4.0 4.0 4.5

2900

12.43 15.85 16.34

46 55 56

Y160L-2YB18.5

Y180M-2YB22

Y200L1-2YB30

CQB-G 100-65-200

60 100 120

54 50 47

4.0 4.0 4.5

2900

21.01 25.69 28.44

42 53 56

Y200L1-2YB30

Y220L2-2YB37

Y225M-2YB45

CQB-G 100-65-250

60 100 120

86 80 74.5

4.0 4.0 4.5

2900

37.98 45.39 49.69

37 48 49

Y250M-2YB55

Y280S-2YB75

Y280M-2YB90



CQB-G series magnetic drive pump is suitable for petroleum, chemical, pharmaceutical, smelting, electroplating, environmental protection, food, film and television printing, water treatment, national defense and other industries. It is an ideal equipment for conveying flammable, explosive, volatile, toxic, rare and precious liquids and various corrosive liquids. It is suitable for conveying liquid without hard particles and fibers with suction pressure no more than 0.2MPa, larger working pressure 1.6Mpa, temperature no more than 280 ℃, density no more than 1600kg / m3, viscosity no more than 30 × 10-6m2 / s.


Related information

    Address:576 Wuding Road, Jing'an District, Shanghai

    E-mail:info@xinguangminggroup.com